RL-120B

Ring Light 120mm 80° blue 470nm M8/4-pin

Implementation of ring lights is very simple – the camera lens passes through the center of the light.

  • Compact design
  • Homogenous light field
  • Universal mounting
Ring Light 120mm 80° blue 470nm M8/4-pin
Active Illumination Area (mm) 120
IP Category IP50
Connector M8/4
Features Strobe, Analogue, Trigger mode
Weight (g) 255
Dimensions (mm) L118xW118xH20
LED Beam Angle 80° LED Beam Angle 120° LED Beam Angle 90° LED Beam Angle 60°
Blue White Ultraviolet Red Infrared Green
LED Wavelength 470 nm LED Wavelength 5700K LED Wavelength 405 nm LED Wavelength 634 nm LED Wavelength 850 nm LED Wavelength 385 nm LED Wavelength 660 nm LED Wavelength 528 nm LED Wavelength 365 nm LED Wavelength 940 nm LED Wavelength 395 nm
Cancel all parameters

LIGHT OPERATING MODES

PERMANENT ILLUMINATION MODE
This light is designed for both the permanent and light-triggering mode.
For permanent illumination bring the voltage of 10-24 V to the pin number 4 (black wire).
The light is ON during the time when the 24 V EN signal is activated.
Use a PCL, camera or another binary signal source.
For the light intensity control, please see the text bellow.

LIGHT TRIGGERING MODE
Light triggering mode saves energy and extends the lifetime of the light.
Trigger operation mode is recommended when a parallel operation of 2 or more lights might affect
the quality of the acquired image.
To start using a triggering mode, bring the pin number 4 (black wire) to a 10-24 V signal.
The light is ON when a voltage signal is present at pin number 4 then.
Use a PCL, camera, or another binary signal source for triggering.
For the light intensity control, please see the text bellow.

STROBE MODE
Strobe function significantly multiplies the maximum intensity of the light.
The strobing function saves energy, extends the light lifetime and in many cases improves the stability of the entire inspections system.
Pin number 2 (white wire) of the M8 connector is used to activate the strobe function.
The maximum strobe pulse time is 10 ms, while the light idle time must be at least 10 times longer, which in this case makes 100 ms.
Bringing a permanent logical 1 signal (10-24 V voltage) to a light strobe input, the light standardly operates in a 10 ms ON and 100 ms OFF cycle.
The strobe operation pulse might be chosen in the time span of 1-10 ms.
Please do not use a trigger mode during strobing function, do not bring a voltage to the pin number 3.

LIGHT SOURCE INTENZITY REGULATION
The light intensity might be regulated by an analogue voltage,
PWM signal or an external controller.
In case of using an analogue signal, the light intensity might be regulated in a linear way at a pin number 4
by the voltage span of 2.7 -10 V.
Bringing a voltage of 10-24 V to the pin number 4, the light works at its maximum intensity.
The maximum PWM frequency is ≤ 40 kHz.

Configuration

Model series Wavelength Datasheet 2D drawing 3D model
RL-120B
470

Principles of use

Dimensions and weights

illustration
Model series A - Outer Ø (mm) B - Inner Ø (mm) C - Height (mm) Weight (g)
RL-120B 118 60 20 255

No question has been asked yet.

Your questions

You must log in to post questions.

Log in

Lost password? How to become partner and display prices

Password recovery

Have you remembered? Return to log in